Respironics Lifecare Ventilator Manufacturer,Supplier and Exporter in India

Respironics Lifecare Ventilator

Product Code : JA-MV-3957
Jainco Lab is a leading Respironics Lifecare Ventilator Manufacturer,and suppliers in India, Respironics Lifecare Ventilator Manufacturer,and suppliers in South Africa, Respironics Lifecare Ventilator Algeria (Algiers), Respironics Lifecare Ventilator Angola (Luanda), Respironics Lifecare Ventilator Argentina (Buenos Aires), Respironics Lifecare Ventilator Armenia (Yerevan), Respironics Lifecare Ventilator Australia (Canberra), Respironics Lifecare Ventilator Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Respironics Lifecare Ventilator

Mode Selection: Control, Control + Sigh, Assist/Control, Assist/Control + Sigh, SIMV.

Tidal Volume: 0.05 to 0.20 ± 0.02 liters; 0.20 to 3.00 liters ± 10%.

Sign Volume: 150% of Set Tidal Volume.

Sign Frequency: 1 Sign Breath every 100 Tidal.

Breath Rate: 2 to 35 BPM ± 0.5; 36 to 40 BPM ± 2..

Aspiratory Flow Rate (Peak flow rate during aspiratory time): 10 to 120 LPM.

Battery Test Switch: Test Internal/External Battery.

Main Power Switch: On/Off, Recharge.

DC Circuit Breaker: Push/Pull Actuation.

AC Circuit Breaker: Push/Pull Actuation.

Airway Pressure Limit:  5 to 100 cm H2O ±  5.

Sensitivity: +18 cm H2O ± 1 to at least -6 cm H2O.

Low Pressure Alarm: 2 to 40 cm H2O ± 2; 41 to 50 cm H2O ± 5.

Manual Sigh: Push to Activate One Breath.


   