Liquid-Liquid Extraction Pilot Plant With Rotating Disc Column Manufacturer,Supplier and Exporter in India
Product Code : JA-CELE-9504
The Liquid-Liquid Extraction Pilot Plant With Rotating Disc Column (SKU JA-CELE-9504) is a glass extraction plant for studying the transfer of a solute between two immiscible liquids. It is listed with a DN50 borosilicate glass extraction column 600 mm high fitted with a disc agitator driven by a motor with tachogenerator, a second DN50 glass column packed with Raschig rings, top and bottom glass separators and two stainless steel metering pumps of 0-40 l/h. This liquid-liquid extraction plant is supplied by JaincoLab for chemical engineering laboratories.
Specifications
The plant runs on 230 V AC, 50 Hz, single phase at 2 kVA, measures 1600 x 900 x 1800 mm and weighs 130 kg; it has four 30 litre plastic tanks for the light phase, heavy phase, extract and raffinate, on a stainless steel frame with castors.
| Product | Liquid-Liquid Extraction Pilot Plant With Rotating Disc Column |
| SKU | JA-CELE-9504 |
| Agitated column | Borosilicate glass, DN50, height 600 mm, disc agitator with motor and tachogenerator |
| Packed column | Borosilicate glass, DN50, height 600 mm, Raschig rings |
| Separators | Top and bottom, borosilicate glass |
| Metering pumps | 2, stainless steel body, 0-40 l/h |
| Tanks | Plastic, 30 litres each - light phase feed, heavy phase feed, extract, refined product |
| Agitator speed | Electronic indicator |
| Frame | Stainless steel, with castors |
| Power supply | 230 V AC, 50 Hz, single phase, 2 kVA |
| Dimensions | 1600 x 900 x 1800 mm |
| Weight | 130 kg |
Experiments with the rotating disc extraction column
Students pump the light and heavy phases counter-currently through the column, vary the disc agitator speed and phase flow rates, and analyse extract and raffinate to find the extraction efficiency.
- Counter-current liquid-liquid extraction
- Effect of agitator speed on extraction efficiency
- Comparing an agitated disc column with a Raschig ring packed column
- Mass transfer coefficient and number of stages calculations
- Mass transfer operations practicals
Scope of supply and ordering
This listing covers the liquid-liquid extraction plant with both glass columns, separators, metering pumps, tanks, agitator drive and frame. Solvents and analytical equipment are not part of the listing.
Single units for one laboratory and complete sets for institutions or projects are both supplied.
Frequently asked questions
Which columns are included?
A DN50 glass column with disc agitator and a DN50 glass column with Raschig rings, each 600 mm high.
What are the pump flow rates?
Two stainless steel metering pumps of 0 to 40 l/h.
What power supply and space does it need?
230 V AC, 50 Hz single phase at 2 kVA; the plant measures 1600 x 900 x 1800 mm and weighs 130 kg.
Related products
- Liquid-Liquid Extraction Pilot Plant With Raschig Ring Packing
- Ternary Systems Study Bench
- Manual Combined Extraction And Distillation Pilot Plant
- Manual Solid Liquid Extraction Pilot Plant
See the complete training workshop labs range for related chemical engineering and training laboratory equipment.
Request a quote
Request pricing for the Liquid-Liquid Extraction Pilot Plant With Rotating Disc Column (SKU JA-CELE-9504) through the JaincoLab contact page, stating the quantity and where it is to be delivered, or write to [email protected]. For tender or project supply, see our tenders page.