Original Generator Manufacturer,Supplier and Exporter in India
Product Code : JA-EF-9746
The Original Generator is a 12 V vehicle-system DC generator, or dynamo, for classroom and workshop training. It is used for demonstrations and exhibits, as a replacement part on engines, or on an alternator and generator test bench. The standard new build gives a nominal 14 V charging output and about 30 A with a compatible regulator. A remanufactured unit is quoted separately with a test report.
Specifications of the 12 V DC generator
| Product code | JA-EF-9746 |
|---|---|
| Type | DC generator (dynamo) for a 12 V vehicle system |
| Charging output | Nominal 14 V* |
| Rated current | About 30 A in the standard new build* |
| Regulator | Compatible regulator* |
| Mounting | Direction of rotation and mounting set for each build; wooden display base as an option |
| Condition | Supplied new as standard; a remanufactured unit is a separate option, quoted in writing with a test report |
| Uses | Demonstration, exhibits, replacement part and alternator/generator test bench work |
| Manufacturer | JaincoLab, Ambala, India |
* Standard JaincoLab specification for new builds.
DC generator practicals in the workshop
- Charging at low speed. Drive the generator on the Automotive Electrical Test Bench and raise the speed slowly. Note the speed at which it starts to charge, and compare it with the Original Alternator.
- Cut-out action. Watch the cut-out close as the output voltage rises above the battery voltage. It opens again when the speed falls, so the battery cannot discharge through the generator.
- Commutator and brushes. Check the armature and field resistance with a Digital Multimeter, and inspect the commutator and the brushes for wear.
Frequently Asked Questions
What does the cut-out relay do in a dynamo charging circuit?
The cut-out connects the generator to the battery only when the generator voltage is higher than the battery voltage. When the engine slows or stops, it opens, so the battery cannot drive current back through the generator and run it as a motor. A cut-out that sticks closed flattens the battery.
Why does a dynamo need a commutator to give direct current?
The armature coils produce an alternating voltage as they turn in the field. The commutator, a ring of copper segments under the brushes, reverses the connection of each coil just as its voltage reverses. The output at the brushes therefore keeps the same polarity.
Why have alternators replaced dynamos on most vehicles?
An alternator charges well even at idle, weighs less for the same output and has no commutator to wear. A dynamo gives little charge at low engine speed. Dynamos remain useful for teaching and for older vehicles, as they show DC generation and regulation clearly.
Does the generator come with a regulator, and is it supplied new?
Yes. The standard new build comes with a compatible regulator and is rated for a nominal 14 V charging output and about 30 A. A remanufactured generator is a separate option, quoted in writing with a test report. Say which you need when you enquire.
What should we state about rotation and mounting when ordering the dynamo?
A dynamo is built for one direction of rotation and a particular mounting, so these are set for each build. Give the engine or the bench drive you will use, or ask for the optional wooden display base if the unit is for an exhibit.
Other automotive electrical components in the range
See the Automotive Electrical Trainers and Components range and more electronics lab equipment from JaincoLab, an electronics lab equipment manufacturer in India.
For a quotation, send the product name and the quantity you need through our contact page. For tender or project supply, see our tenders page.