• +91-85699-09696

Industrial PLC System Manufacturer,Supplier and Exporter in India

Industrial PLC System

Product Code : JA-DAIAPC-9611

The Industrial PLC System is an industrial PLC panel for project work and experimental set-ups in the laboratory. It combines a Siemens SIMATIC S7-1200 CPU 1214C, an SM 1234 analogue module and a 7-inch PROFINET HMI panel. Peripheral devices can be added to extend the system as a course grows.

Specifications of the Industrial PLC System

Product codeJA-DAIAPC-9611
Type and useIndustrial PLC panel for project work and experimental set-ups in school, college and training laboratories
PLCSiemens SIMATIC S7-1200 CPU 1214C DC/DC/DC with an SM 1234 analogue input/output module
Digital inputs and outputs14 digital inputs and 10 digital outputs at 24 V DC
Analogue inputs and outputs6 analogue inputs (2 on the CPU and 4 on the SM 1234 module) and 2 analogue outputs on the module; module channels set to voltage or current mode for each application
Operator panel7-inch PROFINET HMI panel, linked to the PLC over Ethernet
Programming softwareSTEP 7 (TIA Portal) for the PLC and compatible WinCC engineering software for the HMI; the software licence and a programming PC are offered as separate options
Power supply and connections24 V DC panel supply fed from 230 V AC, 50 Hz single-phase mains; protected terminals and Ethernet connection
ExpansionPeripheral devices and further I/O modules can be added to extend the system
ManufacturerJaincoLab, Ambala, India

Using the Industrial PLC System for laboratory projects

  • Sorting line project. Wire the PLC inputs and outputs to the Conveyor System Trainer. Write a program that starts the belt, detects each item as it arrives and sorts it into the right place.
  • Tank level project. Take the 4 to 20 mA level signal of the Level Process Control Trainer into a current-mode input of the SM 1234 module. Scale it to percent of span and switch the pump between a low and a high level.
  • Sequence and timer exercises. Use the Programmable Logic Controller Trainer Modular Application Modules as small plant models. Students write step sequences with timers and counters, then test them on the module.
  • Wiring check before power-up. Measure the 24 V DC supply and each input circuit with a Digital Multimeter. Then switch on and confirm that each input LED lights when its switch closes.

Frequently Asked Questions

How many inputs and outputs should we specify, and how much spare capacity should we leave?
List every switch, sensor, lamp, motor and valve in the planned projects. Count the digital and analogue points separately. Then add spare points for changes and new exercises. Peripheral devices and further I/O modules can be added later, so the panel can grow with the course.

When does a modular PLC with add-on I/O modules suit a lab better than a compact PLC?
A compact PLC suits fixed, small exercises with a set number of points. Choose a modular system when projects change from term to term, when analogue or high-speed signals are needed, or when the I/O count will grow. Modules can then be added without replacing the CPU.

Why does a current-loop analogue signal start at a live zero instead of zero current?
In a 4 to 20 mA loop, 4 mA means zero on the scale and 20 mA means full scale. A broken wire gives no current at all, so the PLC can tell a fault from a true zero reading. The live zero also lets a two-wire transmitter take its power from the loop.

What kind of projects can students build on an industrial PLC system?
Typical projects are a fluid tank that fills and drains, a washing machine cycle, a conveyor that sorts parts and a traffic junction. Each project starts with a written sequence, then wiring, programming, testing and fault finding. Later projects can add analogue control and a network link.

Which ports should we ask for so the PLC can link to our HMI panels and drives?
The CPU has a PROFINET (industrial Ethernet) port, which links it to the 7-inch HMI panel and to the programming PC. For drives or panels of your own, list the make, model and protocol of each one in your enquiry so the connection can be checked. Send the details through our contact page.

Can we get spare I/O modules and parts for the PLC system after supply?
Ask for a list of recommended spares, such as I/O modules, fuses and patch cords, with the quotation. They can then be ordered with the system. JaincoLab service engineers handle installation and after-sales service at your site. Send the quantity you need through our contact page.

Other PLC trainers in the range

See the Data Acquisition, Instrumentation and Process Control range and more electronics lab equipment from JaincoLab, an electronics lab equipment manufacturer in India.

For a quotation, send the product name and the quantity you need through our contact page. For tender or project supply, see our tenders page.

Last updated: 20 November 2026

   

Office Address

Jain Scientific Suppliers
2475-84, Hargolal Road,
Ambala Cantt, Haryana, India

[email protected]

+91-85699-09696

Follow Us