Microprocessor UV - VIS Spectrophotometer Double Beam (Two Cell Holder)

Product Code : JA-S-6445

The Microprocessor UV - VIS Spectrophotometer Double Beam (Two Cell Holder), SKU JA-S-6445, measures absorbance and transmittance from 190 to 1100 nm with a 1.0 nm spectral bandpass, using tungsten halogen and deuterium light sources. This double beam spectrophotometer keeps baseline flatness within ±0.001 A and drift below 0.002 A/h at 500 nm, and it runs on 110 V 60 Hz or 220 V 50 Hz. It is supplied by JaincoLab for research, pharmaceutical and postgraduate laboratories.

Specifications

The instrument covers 190-1100 nm at 1.0 nm bandpass with ±0.3 nm accuracy, 0.2 nm repeatability and a photometric range of 0-200%T and -0.3 to 3.0 A.

Product Microprocessor UV - VIS Spectrophotometer Double Beam (Two Cell Holder)
SKU JA-S-6445
Wavelength range 190-1100 nm
Spectral bandpass 1.0 nm
Wavelength accuracy ±0.3 nm
Wavelength repeatability 0.2 nm
Baseline flatness ±0.001 A
Stray light 0.05% at 220 nm and 360 nm
Photometric range 0-200%T, -0.3 to 3.0 A
Noise 0.001 A at 500 nm
Drift Less than 0.002 A/h at 500 nm
Light source Tungsten halogen and deuterium
Power AC 110 V / 60 Hz or 220 V / 50 Hz
Dimensions 625 x 430 x 206 mm (L x W x H)
Net weight 26 kg
Cell holder Two cells

Applications of the double beam spectrophotometer

Low noise and drift make this model suited to long spectral scans and to measuring weak absorbances.

  • Spectral scanning in research and postgraduate laboratories
  • Pharmaceutical assay and dissolution sample analysis
  • Biochemical measurements in biotechnology laboratories
  • Environmental and water analysis

Scope of supply and ordering

The listing covers the double beam spectrophotometer with tungsten halogen and deuterium lamps and two cell holder. Cuvettes, printer, software and spare lamps are confirmed on the quotation.

Minimum order quantity, lead time and packing are confirmed on each quotation for the number of instruments and the delivery destination.

Frequently asked questions

What bandpass does it have?
1.0 nm, over a range of 190 to 1100 nm.

How stable is the baseline?
Baseline flatness is ±0.001 A, with drift below 0.002 A/h at 500 nm.

Which mains supplies does it accept?
AC 110 V / 60 Hz or 220 V / 50 Hz.

Related products

This model is listed in the JaincoLab spectrophotometer range.

Request a quote

To order the Microprocessor UV - VIS Spectrophotometer Double Beam (Two Cell Holder), send the quantity and delivery destination through the JaincoLab contact page or email [email protected], quoting SKU JA-S-6445. Tender and project enquiries can be sent through the tenders page.

Last updated: September 2026

   

Office Address

Jain Scientific Suppliers
2475-84, Hargolal Road,
Ambala Cantt, Haryana, India

[email protected]

+91-85699-09696

Follow Us