150 MHz RF Signal Generator Manufacturer,Supplier and Exporter in India
Product Code : JA-SG-1545
The 150 MHz RF Signal Generator covers 100 kHz to 150 MHz in six bands, with third-harmonic output up to 450 MHz. It gives AM test signals from an internal 1 kHz tone or an external source. A built-in frequency meter reads 10 Hz to 150 MHz. A calibrated 50 ohm RF version can be ordered as an option.
Specifications of the 150 MHz RF signal generator
| Product code | JA-SG-1545 |
|---|---|
| Frequency bands | A 100 to 300 kHz; B 300 kHz to 1 MHz; C 1 to 3.2 MHz; D 3 to 10 MHz; E 10 to 35 MHz; F 32 to 150 MHz (fundamental) |
| Harmonic output | Third harmonic up to 450 MHz |
| RF output | 100 mVrms at 35 MHz; 0 dB / 20 dB step and fine level control |
| Modulation, standard model | AM from an internal 1 kHz tone or an external 50 Hz to 20 kHz signal (input below 1 Vrms) |
| Audio output | 1 kHz fixed, at least 1 Vrms |
| Built-in frequency meter | Low range 10 Hz to 10 MHz (accuracy 1 Hz); high range 10 MHz to 150 MHz (accuracy 10 Hz); input sensitivity below 50 mV; maximum input about 3 Vrms |
| Calibrated RF option | Order option: 50 ohm BNC output set from -100 to 0 dBm; frequency reference within ±10 ppm |
| Modulation, calibrated option | AM depth up to 90%; FM deviation up to 50 kHz, within the carrier limits |
| Operating temperature | 0 to 40 °C |
| Manufacturer | JaincoLab, Ambala, India |
Receiver and RF circuit practicals with the 150 MHz signal generator
- Stage-by-stage alignment. Inject a modulated signal into the AM FM Radio Trainer, starting at the IF amplifier and moving back to the aerial input. Peak each tuned stage for the loudest clean tone, and lower the level as the set comes into line.
- Sensitivity and selectivity. Feed the DSB and SSB AM Receiver Trainer with a modulated carrier and reduce the level until the tone only just stays clear. Then detune slowly to either side to see how selective the IF stages are.
- Reading an oscillator. Connect the output of the RF Oscillators board to the frequency meter input and read the frequency of each circuit. Keep the input below about 3 Vrms.
- Cross-checking the dial. Compare the generator's frequency meter with the Frequency Counter at a few points in every band, and note how closely the tuning dial agrees.
Frequently Asked Questions
How is an RF signal generator used to align the IF stages of a radio receiver?
Set the generator to the receiver's intermediate frequency on the matching band, with the internal 1 kHz tone switched on. Inject it at the mixer through a small capacitor and keep the level as low as gives a clear tone. Adjust each IF transformer for the loudest, cleanest output, working from the detector end back.
Why does the generator have six bands instead of one continuous range?
One tuned oscillator with a single variable capacitor can only cover a limited ratio of frequencies. Splitting 100 kHz to 150 MHz into six bands keeps each range narrow enough for a steady output and readable tuning. Neighbouring bands meet or overlap, so no frequency in the range is missed.
How is the third-harmonic output used above 150 MHz?
Every oscillator also gives weaker signals at whole multiples of its frequency. With the generator tuned in its top band, the third harmonic reaches up to 450 MHz. That is enough to check a VHF or UHF front end or tuned circuit. The harmonic is much weaker than the fundamental, so allow for that when judging levels.
Why should the RF output be kept low when testing a receiver?
A strong signal overloads the RF and IF stages, and the AGC then hides the faults you are trying to find. Use the 20 dB step and the fine control to bring the level down until the tone is only just clear. Short, screened leads also stop the signal leaking in around the set.
What does the calibrated RF option add when a tender asks for output in dBm?
The calibrated RF option is chosen when ordering. It has a 50 ohm BNC output set from -100 to 0 dBm and a frequency reference within ±10 ppm. It adds AM depth up to 90% and FM deviation up to 50 kHz within carrier limits. Name this option in your enquiry if the tender lists dBm output or FM.
Can your team show our staff how to use the generator for receiver work?
Yes. A JaincoLab team can give a demonstration at your institution, and service engineers install instruments and look after them at your site. A service manual is available with the generator. Ask for the demonstration when you send your enquiry through our contact page.
Other generators in the signal generator range
- 2 MHz Function Generator
- 5 MHz Function Generator
- 10 MHz Function Generator
- 13 MHz Function Generator
- 15 MHz Function Generator
- 2 to 5 MHz AM and FM Function Generator
See the Signal Generators range and more electronics lab equipment from JaincoLab, an electronics lab equipment manufacturer in India.
For a quotation, send the product name and the quantity you need through our contact page. For tender or project supply, see our tenders page.